this post was submitted on 21 Dec 2023
606 points (98.2% liked)

memes

10223 readers
1653 users here now

Community rules

1. Be civilNo trolling, bigotry or other insulting / annoying behaviour

2. No politicsThis is non-politics community. For political memes please go to [email protected]

3. No recent repostsCheck for reposts when posting a meme, you can only repost after 1 month

4. No botsNo bots without the express approval of the mods or the admins

5. No Spam/AdsNo advertisements or spam. This is an instance rule and the only way to live.

Sister communities

founded 1 year ago
MODERATORS
 
you are viewing a single comment's thread
view the rest of the comments
[–] [email protected] 69 points 10 months ago (6 children)

They would still trip in this case

[–] [email protected] 50 points 10 months ago (1 children)

Yeah, the switch isn't the breaker it's just the reset is my understanding.

[–] [email protected] 9 points 10 months ago (3 children)

So would this reset immediately or not reset at all?

[–] [email protected] 35 points 10 months ago

Not at all, it has to be flipped off before you can turn it back on.

[–] [email protected] 10 points 10 months ago (2 children)

When a breaker pops the switch moves to the middle, to reset, you have to turn it all the way off and then back on. If it's in the middle and you go straight to on then it's just springy and nothing happens, and it moves back to the middle.

So yeah, ruins the joke but nothing's compromised here.

[–] [email protected] 8 points 10 months ago

That actually is good context tho. Ive sometimes turned a switch from middle to on and wondered why it did nothing and then turned them all off and on and it worked. I assumed i was flipping the wrong switch

[–] [email protected] 4 points 10 months ago

Thanks!

So yeah, ruins the joke but nothing's compromised here.

I wouldn't say you ruined the joke but used it as an opportunity to teach. Thanks again

[–] [email protected] 4 points 10 months ago (1 children)

Would not reset at all.

Basically, the breaker has an internal switch and an external operating handle. When it trips, the internal mechanism of the breaker disengages the internal switch from the external handle, and flips the internal switch to its open position. The handle can't toggle the internal switch while it is disengaged.

To re-engage, you have to move the handle to the full "off" position. The internal switch re-engages the handle, and the handle can now toggle the switch again.

This breaker cannot be shut off manually, nor can it be reset manually. But, it can still trip in case of a fault.

It's kinda like if you have a pushbutton start car, but you drop off the passenger who has the key fob. The car will continue running until it is shut down or stalls out. But once that happens, you can't restart it without the key fob.

[–] [email protected] 1 points 10 months ago

Neat, that's a really clever mechanism

[–] [email protected] 11 points 10 months ago

...over the stack of plugs sticking so far out from the wall.

[–] [email protected] 7 points 10 months ago

Yeah just makes it harder to reset

[–] [email protected] 4 points 10 months ago

I highly doubt those LEDs are drawing over 20A in the first place. Those lights only draw like 0.2W per ft, or 69W per 1k LEDs.

You'd need nearly 35,000 LEDs, or about 12,000ft of lights to trip the breaker.

[–] [email protected] 3 points 10 months ago

Yeah the best option is to just bypass the breaker box completely.