Contractor installed this convoluted p-trap + elbow for the washer, and I'm not sure if it's up to code. Can you confirm and more importantly explain why or why not it's compliant?

you are viewing a single comment's thread
view the rest of the comments
[โ€“] [email protected] 16 points 1 day ago (1 children)

I'm sorry but ..... what an absolute mess

You mentioned that your main drain is a bit higher than the floor of the basement. I have the same situation, my drain is about two feet off the floor of my concrete basement. The washing machine drain was placed to drain towards the lowest point of the main drain. Everything else in the house with a drain is in upper floors.

I'd rearrange the plumbing to build a drain as close to the four foot level as possible for the washing machine .... instead of trying to build a solution 6 or 7 feet up in the air ... you're asking for trouble if you are making your washing machine drain up to a high point.

I remember once renting a place that was an old house with a brand new concrete basement .... the main drain was close to ground level that went to a septic tank and field. Their solution was to install the washing machine in the basement, drain down to the floor level, then to a grey water pump unit in a big box that was 3x3x3 feet .... and that pushed the water up to the main drain. I don't think washing machines are meant to push water that high up and you will probably constantly have a bit of grey water backing down to the washing machine.

[โ€“] [email protected] 3 points 1 day ago (1 children)

I've got a similar situation to your rental for my basement (the main floor drains separately). There's a macerator/pump combo in an 8ish gallon tank in a pit cut through the foundation (lined with concrete) that elevates to the main drain outside the house. The pump failed a couple years ago and was not fun to deal with. Luckily it was exclusively laundry that day. Everything connected to it is vented.

When we get pushed to connect to sewer (one way or another), my plan is to get a bit silly and connect at the lowest level so we can avoid the pump for the future.

[โ€“] [email protected] 5 points 22 hours ago (1 children)

When you do get that connection ... go the extra step and install a 'backwater prevention valve' ... it's a giant one way valve that is attached to the main drain line as it leaves the house.

It allows water to always easily flow out but if it ever happens that water back flows into your house for some reason ... the valve will stop any flow from entering your house.

I've always planned to get one but my situation is too difficult to install one.

[โ€“] [email protected] 3 points 21 hours ago

That does seem pretty obligatory. We have the same thing on our irrigation (don't want irrigation water backflowing in to the drinking water, and also it's required).

We are at the top of a hill and everything flows down from us to the entire neighborhood, so that is another good check on the issue.